VKX 5030C Dual energy baggage x-ray scanner machine
General information of x ray scanner
Tunnel Size : W506mm x H300mm
Speed : 0.20 m/s
Height of Transmission Belt : 664 mm
Maximum Load : <100 kg (Adequate distribution)
Wire Resolution : 38 AWG (0.0787mm metal wire)
Space Definition : Horizontal ① 1.0mm \ Vertical ①1.0mm
Penetrate Definition : 34 AWG
Penetration : 38mm Steel board
Monitor : 19 inch LED
System Function : High density alarm, Explosive/Drug auxiliary detect, TIP, Luggage counter.
System running timer, X-ray emitting timer.
Training, 64 times continuous zoom in
Film Safety : ASA/ISO1600 standard of film safety
X-ray System
Tube Voltage : 140 Kv
Cooling : Seal oil cooling /100%
Single Inspection Dosage Rate : <1.0(i Gy
Radiation Leak Dosage : 0.1 卩 Gy/h (5cm from the surface)
Installation Specification
Package Size : 1475mm (L) * 784mm (W) * 1100mm (H)
Console Desk Size :1690mm (L) * 870mm (W) * 1330mm (H)
Package Weight: 220KG Consumption : 0.5 kVA
Noise : 53.8 dB(A)
More thins about x ray baggage scanner machine